Oscilloscope GW Instek GDS-1072A-U băng thông 70 MHz, lấy mẫu 1 GSa/s, 2 kênh, bộ nhớ 2 Mpts/kênh, màn hình 5.7 inch.
The GDS-1000A-U series provide a unique solution. The GDS-1000A-U lineup includes GDS-1152A-U, GDS-1102A-U and GDS-1072A-U three models. Operating at 150, 100 or 70 MHz with a real-time sampling rate of 1GSa/s, the GDS-1072A-U employs MemoryPrime technology. Using MemoryPrime technology, the GDS-1072A-U is able to overcome the problems associated with memory constraints. High sample rates, rarely found in traditional DSOs, can be maintained over longer periods of time, without effecting performance.
Coupled with the high resolution 5.7” color TFT display, with user-friendly interface USB device and host port make the GDS-1000A series feature-rich.
About MemoryPrime Technology
What is the single feature lacking from most digital storage oscilloscopes? Adequate memory depth. Is the memory depth of your DSO large enough?
With 2M points of memory, the GDS1072A-U has the capability to acquire far more waveform data compared to other DSOs in the same performance range.
The 1GSa/s sampling rate and 2M point memory play an extremely powerful role for single-shot waveform capture. Properly set the trigger conditions to baby-sit the expected waveform. When the single-shot waveform is triggered and captured, you are able to check and see the single-shot event without losing any detailed information. A DSO, with high sampling rate but short memory, can't do the job of single-shot waveform capture as well as the GDS1072A-U.
Ease of Use
Full-featured acquisition mode and 27 auto measurement functions help users to measure the parameters of captured waveforms accurately. The advanced Auto-Set function enables GDS-1000A-U Series to catch waveform automatically and display waveform quickly. With Arithmetic functions, +, -, x, FFT, FFTrms and Zoom FFT. GDS1072AU Series keep users aware of the measurement results by updating values immediately. Without almost extra calculation, GDS-1072A-U can provide sufficient information of testing.
Observation-Delay ON/OFF
For the convenience of waveform observation and analysis, the GDS1072AU includes Delay On/Off functions usually available only in the higher end products. With Delay On, a signal can be observed from an offset of the trigger point. This feature allows the horizontal scale and the waveform scale to be expanded and centered on the delay point rather than the trigger point, allowing a signal to be observed in detail where needed.
Observation-Expand by Ground/Center
In a DSO, "AC Coupling" is normally used to isolate the AC components of a signal by blocking the DC components. This is useful to see a signal with a small AC component that is offset with a large DC voltage. With AC coupling to block the DC voltage, small AC waveforms can be observed from the center of the screen for measurement or examination. However, capacitive loading under AC coupling mode may cause waveform distortion as low frequency components become degraded, an effect that needs to be avoided in frequency critical applications. The Expand by Ground and Center functions are convenient tools to expand a waveform vertically. With this feature, the vertical scale of a waveform can be expanded either from the ground reference or from the center of the screen without causing capacitive loading.
FFT/FFTrms and Zoom FFT Measurement
The FFT math function on a digital storage oscilloscope is often used to observe the fundamental and harmonic components of a signal. Typically the traditional unit of the FFT is a decibel (dB). However in the use of dB, it is difficult to identify the fundamental frequency of a signal from a noisy spectrum sometimes. With the FFTrms function, the GDS-1000A-U series can clearly display the fundamental frequency of an acquired waveform. With the FFTrms function, the GDS-1000-A-U series can clearly display the fundamental frequency of an acquired waveform. Zoom FFT provides users with observation flexibility that they can move FFT waveform horizontally and zoom it up to 20X to investigate details of FFT signal.
PC Remote Control Software
Using a USB port coupled with FreeWave remote monitoring software is the easiest and most convenient way to capture data from the GDS1072A-U. With FreeWave, a screenshot can be saved as an image file (.bmp/.jpg), waveform data(.csv) can be logged, and movie files(.wmv) can be recorded in real-time. Not only can FreeWave monitor and record waveforms over a long period of time, but previously recorded waveforms can also be observed. Instrument settings can even be configured without the need to learn incomprehensible command line syntax. With the simple user interface and robust features, FreeWave allows you to get the most out of the GDS1072A-U with little effort.
USB Host & Data Logger
USB host function enable user to store waveform setting ,data or image on USB flash disk. Furthermore, the data logger can continue monitoring input signals and storing their waveform data in USB flash disk when trigger conditions are met, saving users' effort to tracking signals manually and allowing them to analyze and observe waveform data afterwards.
Go/NoGo Function
Go/NoGo testing function check whether the incoming signal violates the user-defined template. Users can easily define this template by setting the tolerance ratio to determine violation conditions. Go/NoGo testing can either keep counting violation number or stop testing when violation conditions are met.
GDS-1072A-U | GDS-1102A-U | GDS-1152A-U | |
VERTICAL | |||
Channels | 2 | 2 | 2 |
Bandwidth | DC~70MHz(-3dB) | DC~100MHz(-3dB) | DC~150MHz(-3dB) |
Rise Time | <5ns Approx. | <3.5ns Approx. | <2.3ns Approx. |
Sensitivity | 2mV/div ~ 10V/div (1-2-5 increments) | ||
Accuracy | ±(3% x |Readout| + 0.1 div + 1mV) | ||
Input Coupling | AC, DC & Ground | ||
Input Impedance | 1MΩ±2%, ~15pF | ||
Polarity | Normal & Invert | ||
Maximum Input | 300V (DC+AC peak), CATII | ||
Waveform Signal Process | + , - , x, FFT, FFTrms ,Zoom FFT | ||
Offset Range | 2mV/div ~ 50mV/div: ±0.4V 100mV/div ~ 500mV/div: ±4V 1V/div ~ 5V/div: ±40V 10V/div: ±300V | ||
Bandwidth Limit | 20MHz (-3dB) | ||
TRIGGER | |||
Sources | CH1 , CH2 , Line , EXT | ||
Modes | Auto, Normal, Single, TV, Edge, Pulse Width | ||
Coupling | AC , DC , LF rej. , HF rej. , Noise rej. | ||
Sensitivity | DC ~ 25MHz: Approx. 0.5div or 5mV; 25MHz ~ 70/100/150MHz: Approx. 1.5div or 15mV | ||
EXT TRIGGER | |||
Range | ±15V | ||
Sensitivity | DC ~ 25MHz : ~ 50mV ; 25M ~ 70/100/150MHz : ~15mV | ||
Input Impedance | 1MΩ±2% , ~ 15pF | ||
Maximum Input | 300V (DC AC peak) , CATII | ||
HORIZONTAL | |||
Range | 1ns/div ~ 50s/div (1-2.5-5 increments); ROLL : 50ms/div ~ 50s/div | ||
Modes | Main, Window, Window Zoom, Roll, X-Y | ||
Accuracy | ±0.01% | ||
Pre-Trigger | 10 div maximum | ||
Post-Trigger | 1000 div | ||
X-Y MODE | |||
X-Axis Input | Channel 1 | ||
Y-Axis Input | Channel 2 | ||
Phase Shift | ±3°at 100kHz | ||
SIGNAL ACQUISITION | |||
Real-Time Sample Rate | 1GSa/s maximum | ||
Equivalent Sample Rate | 25GSa/s maximum | ||
Vertical Resolution | 8 Bits | ||
2 Mega Points maximum | |||
Acquisition Mode | Normal, Peak Detect, Average | ||
Peak Detection | 10ns (500ns/div ~ 10s/div) | ||
Average | 2 , 4 , 8 , 16 , 32 , 64 , 128 , 256 | ||
CURSORS AND MEASUREMENT | |||
Voltage Measurement | Vpp ,Vamp ,Vavg ,Vrms ,Vhi ,Vlo ,Vmax ,Vmin ,Rise Preshoot/Overshoot ,Fall Preshoot/Overshoot | ||
Time Measurement | Freq ,Period ,Rise Time ,Fall Time ,Positive Width ,Negative Width ,Duty Cycle | ||
Cursors Measurement | Voltage difference between cursors (V) Time difference between cursors (T) | ||
Auto Counter | Resolution : 6 digits Accuracy: 2% Signal Source: All available trigger source except the Video trigger mode | ||
ADJUSTABLE PROBE COMPENSATION SIGNAL | |||
Frequency Range | 1kHz ~ 100kHz, 1kHz/STEP | ||
Duty Cycle Range | 5% ~ 95%, 5%/STEP | ||
CONTROL PANEL FUNCTION | |||
Autoset | Adjust Vertical VOLT/DIV, Horizontal TIME/DIV, and Trigger level automatically | ||
Save Setup | Up to 15 sets of measurement conditions | ||
Save Waveform | 15 sets of waveform | ||
DISPLAY | |||
TFT LCD Type | 5.7 inch | ||
Display Resolution | 234(Vertically) x 320(Horizontally) Dots | ||
Display Graticule | 8 x 10 divisions | ||
Display Brightness | Adjustable | ||
INTERFACE | |||
USB Device | USB1.1 & 2.0 full speed compatible | ||
USB Host | Image (BMP), waveform data (CSV), and setup (SET) | ||
POWER SOURCE | |||
Line Voltage Range | AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection | ||
MISCELLANEOUS | |||
Multi-Language Menu | Available | ||
Onscreen Help | Available | ||
DIMENSIONS & WEIGHT | |||
310(W) x 142 (H) x 140(D)mm, Approx. 2.5kg |
User manual x 1, Power Cord x 1 Probe GTP-070A-4 or equivalent : 70MHz (10:1/1:1) Switchable passive probe for GDS-1072A-U (one per channel) Probe GTP-100A-4 or equivalent : 100MHz (10:1/1:1) Switchable passive probe for GDS-1102A-U (one per channel) Probe GTP-150A-2 or equivalent : 150MHz (10:1/1:1) Switchable passive probe for GDS-1152A-U (one per channel) Optional Accessories GSC-006 Soft carrying case GTL-110 Test lead, BNC-BNC heads GTL-242 USB 2.0 A-B type cable