Description
DURO A1 SINGLE-BAY BATTERY CHARGER
This compact single-bay charger services lithium and nickel based battery packs. The external 18-watt AC power supply provides 15 watts of charge power per bay. Charge time is 2-3 hours, depending on battery size.
Part Number: 11-403-0100 |
DURO A5 MULTI-BAY BATTERY CHARGER
Has a 90-watt external AC power supply to provide 15 watts of charge power per bay. Charge time is 2-3 hours, depending on battery size.
Part Number: 11-403-0500 |
DURO B1 SINGLE-BAY BATTERY CHARGER
Charges SMBus and non-SMBus batteries. A 30-watt external AC power supply provides 27 watts of charge power per bay for a charge time of 2-3 hours on most batteries.
Part Number: 11-403-0120 |
DURO B5 MULTI-BAY BATTERY CHARGER
Similar to B1 with 5 bays for simultaneous service of 5 batteries; includes battery calibration & conditioning function on bays 1 and 2. A 150-watt external AC power supply provides 27 watts of charge power per bay.
Part Number: 11-403-0520 |
HOT AND COLD CHARGING
Advanced charge techniques guarantee full state-of-charge and safe operation even under adverse conditions. Below 0C (32F), the Duro applies a trickle charge to warm up the nickel-based battery, then switches to fast-charge on reaching operating temperature. A charge time-out timer prevents a prolonged charge at low temperature. For safety reasons, lithium-ion does not charge below 5C (41F).Above 50C (123F), the Duro allows the battery to cool down to 45C (113F) before taking on a charge or resuming from a previous charge. Should the temperature remain high, a time-out timer terminates the battery with a fail indication. Preventing charge at high temperatures protects battery and equipment and achieves optimal safety.* Temperature sensing requires a thermistor in the battery or in the adapter |
FULL-CHARGE TERMINATION
The termination methods of nickel-based batteries are based on negative delta V, plateau timer and dT/dt. Lithium-ion terminates on a current saturation. Redundant detection methods provide safe charging, even if the battery is known to be defective. |
TRI-CHEMISTRY SELECTION
The user often has the choice of utilizing nickel or lithium-based batteries. Duro adapters automatically detect the battery type and select the correct charge algorithm. Nickel and lithium-based batteries can be charged in the same adapter.* * Only for batteries with usable identification code |
ACTIVE CHARGE OPERATION
Operators often require monitoring voice traffic while the radio is in the charger. The Duro makes this possible by applying a topping charge after energy has been dispensed. With the Duro charger, a two-way radio can in essence become a base station. |
SIGNAL INDICATORS
Two light signals indicate charging, ready and fail status. Fail denotes a battery that is shorted, unable to follow the predicted voltage pattern or other anomalies. A fail condition terminates service to protect the battery and charger and alerts the user with a flashing red LED. |
REACTIVATING LITHIUM-ION BATTERIES
When discharged too low, some lithium-ion batteries appear dead and cannot be recharged. The Duro charger recognizes this condition and reactivates the pack’s safety circuit with charge pulses. On reaching normal voltage, a fast-charge completes the charge. |
CONDITIONING / CALIBRATION DISCHARGE
Bay 1 and 2 of the Duro B5 are equipped with discharge circuits. This feature reverses memory on nickel-based batteries and calibrates SMBus packs. Batteries in constant use should be serviced once every 1-3 months to prolong battery life and retain an accurate digital readout. The B5 recognizes the need for calibration by flashing the red LED for 15 seconds. |
CHARGES SMBUS BATTERIES
The Duro B-system services SMBus batteries by communicating with the internal battery flags and resetting the state-of-charge indicator on full charge. |
IN-VEHICLE MOUNTING
The Duro chargers can be installed in a vehicle to service 3.6 to 7.2 volts batteries. Higher voltage batteries can be serviced by adding a third-party external DC-to-DC converter. Cadex offers several mounting options that allow horizontal or vertical mounting. Typical charger locations are the transmission hub, firewall, trunk floor and the wall in a truck. The installation is quick and simple. |
SYSTEM SPECIFICATIONS
Duro A1 | Duro A5 | Duro B1 | Duro B5 | |
System | 1-bay quick-charger for regular batteries | 5-bay quick-charger for simultaneous charge of 5 batteries | 1-bay quick-charger for SMBus batteries; also charges regular batteries | 5-bay quick-charger for simultaneous charge of 5 regular and SMBus batteries |
Battery interface | The chargers are factory configured for the battery type. Customer specified. | |||
Chemistries | Nickel-cadmium (NiCd), nickel-metal-hydride (NiMH) and lithium-ion (Li-ion). | |||
Charge protocol | Nickel-based: Constant current; charge termination: dT/dt (rate-of-temperature increase); 1°C/min. rise, NDV 8-10mV/cell; plateau timer; trickle charge of 0.05C when ready. Lithium-based: Constant voltage, current limit; charge termination on current drop to 0.05C. | |||
Temperature management | Nickel-based: Trickle charge if below 0°C, normal charge when warm Lithium-based: No charge if below 5°C, resumes charge when warm No charge for all chemistries above 50°C; resumes when cooled down to 45°C. | |||
Battery mAh/V | 500mAh - 8000mAh | |||
Low-V version High- V version | 3.60 - 7.20V 8.40 - 14.40V | 3.60 - 7.20V 8.40 - 14.40V | Special order 9.60 - 14.40V | Special order 9.60 - 14.40V |
Charge time | Nickel-based chemistries: 90 minutes typical; longer on larger batteries Lithium-based chemistries: 3h typical; longer on larger batteries | |||
Discharge power | Not available | Not available | Not available | 1A, 15W max each for bays 1 & 2 |
Light signals | Charging: Flashing green Ready: Solid green Fail: Solid red | Same, red/green discharging; flashing red hint to calibrate | ||
Electrical | 18 watts external AC power adapter, (90-250 VAC, 47-63 Hz) | 90 watts external AC power adapter, (90-250 VAC, 47-63 Hz) | 30 watts external AC power adapter, (90-250 VAC, 47-63 Hz) | 150 watts external AC power adapter, (90-250 VAC, 47-63 Hz) |
Vehicle mount | Charges 3.6 - 7.2V batteries from 12VDC vehicular power source | |||
Approvals | CSA 60950, UL60950, EN 60950 for safety and FCC Part 15 Class A, EN55022 Class A for EMI, and EN61000-3-2, EN61000-3-3 and EN61000-4-2, -3, -4, -5, -6, -11 for EMC. RoHS and WEE compliant | |||
Environmental | Operating temperature: 0°C to +40°C (32°F to +104°F) Storage temperature: -30°C to +70C (-22 to +158°F) | |||
Physical Length Width Height Weight | 232.4 mm (9.15”) 127 mm (5”) 57 mm (2.24”) 0.4 kg (0.88 lb) | 520.7 mm (20.5”) 232.2 mm (9.14”) 57 mm(2.24”) 3.25 kg (7.16 lb) | 232.4 mm (9.15”) 127 mm (5”) 57 mm (2.24”) 0.4 kg (0.88 lb) | 520.7 mm (20.5”) 232.2 mm (9.14”) 57 mm(2.24”) 3.25 kg (7.16 lb) |
Warranty | Cadex warrants the analyzer against defective materials and workmanship for a period of one (1) year from the original purchase date. |