RBSSA3X25 Reflection Bridge for Spectrum Analyzer

RBSSA3X25 Reflection Bridge for Spectrum Analyzer

SKU:
RB3X25
Brand:
Warranty:
N/A
Price: Contact
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Product Introduction   

The Siglent RBSSA3X25 is used in connection with SIGLENT’s SSA3000X series of spectrum analyzers to measure S11-related parameters such as return loss, reflection coefficient and VSWR. The RBSSA3X25 also provide 2 N(M)-N(M) adapters to facilitate connection with the SSA3000X’s ports. 

The reflection bridge has 3 ports as shown in the figure: 

-IN(TG):Signal input terminal.This terminal connects to the TG terminal of the spectrum analyzer  
-OUT(RF):Signal output terminal. This terminal connects to the RF input terminal of the spectrum analyzer  
-DUT: This port is connected to the Device Under Test The distance between the SSA3000X’s TG and Input ports is designed to match that on the RBSSA3X25 in order to improve accuracy by eliminating the need for extra cables. 

Reflection Bridge 1MHz - 2500MHz RB3X25 -1

Measurement Procedure 

Reflection Bridge 1MHz - 2500MHz RB3X25 -1

 

1.Connection 

The connection of RBSSA3X25 and spectrum analyzer is shown in the figure to the right: 

Use 2 N(M)-N(M) adapters to connect the output terminal of the tracking generator and the RF input terminal of the spectrum analyzer to the IN terminal and OUT terminal of the reflection bridge respectively. 

2. Measurement procedure 

1) Press Mode -> Reflection Meas, to access the Reflection Measurement mode. The Tracking Generator and the Tracking Generator indicator light will activate and the screen will appear as below: 

Reflection Bridge 1MHz - 250MHz RB3X25 -2 

2) In the Reflection Measurement mode the user can modify certain spectrum analyzer parameters such as Frequency, Amplitude and BW, in those related menus.  

User Manual 

3) Connect the DUT terminal of Reflection Bridge with an open load, or leave it unterminated. Press Cal Open Load. The analyzer screen will now appear as below: 

Reflection Bridge 1MHz - 250MHz RB3X25 -3 

4) Connect the device under test with the DUT terminal of the reflection bridge. The cables or adapters between the DUT and bridge should as short as possible, in order to reduce extra mismatches. The resulting display appears as below. The trace on the screen is the return loss of the device under test.  

Reflection Bridge 1MHz - 250MHz RB3X25 -4 

5) Press Marker, select a Marker (1-4), and Press Marker status ->On to open multiple Markers. Move the position of the Marker and the Reflection Table will display the frequency, return loss, reflection coefficient and VSWR at that Marker point. The Scale is used to set the value of the grid’s vertical scale. The Ref level sets the maximum value (top line) shown on the screen.  

6) To quit the Reflection Measurement Mode, press Mode -> Spec Analyzer 

Specifications 

Frequency range  1 MHz - 2000 MHz 
Connector type N(Female) 
Impedance 50 Ω 
Insertion loss IN to DUT: 5 dB(typical) 
Directivity 1 MHz - 2.0 GHz 2.0 GHz - 2.5 GHz 
 20 dB (typical)  15 dB (typical) 
Size& Weight 136 mm ×75 mm × 30 mm, 0.5 kg  

Hướng dẫn sử dụng

Accessories

Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!

Review about this product: