Rogowski AC Current Probe Micsig RCP500

Rogowski AC Current Probe Micsig RCP500

SKU:
RCP500
Brand:
Warranty:
N/A
Price: Contact
  • Probe Type:
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Description

The RCP500 Rogowski AC Current Probe measures AC current up to 500A pk, minimum to 200mA pk, with bandwidth ranging from 15Hz to 300KHz, 1% accuracy, and has less than 2mV noise.

It adopts the Rogowski coil current measurement system: within the range, the output signal of the system and the current signal to be measured are always linear, so the accuracy will not change with the current; the coil does not contain magnetic saturation components and no magnetic core and saturation phenomenon, no trouble of heating; the Rogowski coil does not contain ferromagnetic materials and so has no hysteresis effect, the phase difference between the output signal and the current waveform is extremely low, which can be less than 0.8° .

     Model                                                                                                RCP500   
Bandwidth15-300KHz   (-3dB )     
Current range 200mApk-500Apk   
Output ConnectorPowered BNC / External BNC
Output Sensitivity10mV/A   
Typical Accuracy1%   
Phase Accuracy ≤0.8° (45Hz-66Hz)   
Temperature CoefficientOperating temp. range + 0.05 × Accuracy Specification /℃ (23℃±5℃) 
Conductor Positional AccuracyWithin ±1% (Deviation from the Center)
Influence of External Magnetic Fields1.5% f.s. or below (400A/m,50Hz/60Hz)
Offset Voltage±1mV or below  
Max VoltageAC 10kV RMS (1 minute), (50Hz/60Hz) (Rogowski coil part only)
Output ImpedanceHigh resistance
Output Noise<2mv rms   
Conductor Under Test Diameter≤Φ50mm   
Power SupplyDC 5V   
Coil to Integrator Cable Length  2m (customizable)  
Integrator Dimensions37*22*82mm   
Rogowski Coil Inner Diameter50mm(customizable) 
Rogowski Coil ThicknessApprox. φ6mm  
Environmental Characteristics
Operating Temperature-20-70℃   
Storage Temperature-30℃-70℃   
Operating HumidityMax 80%,no condensation
Operating Altitude≤ 2000m
Operating PlaceIndoor use, Pollution Degree 2.

Accessories

Oscilloscope AC Current Probe Micsig ACP1000

Contact

High Voltage Differential Probe Micsig DP10007, 100 MHz

Contact

High Voltage Differential Probe DP750-100

Contact

Tablet Oscilloscope Micsig STO1152E, 150MHz, 2CH

Contact

Tablet Oscilloscope Micsig STO1102E, 100MHz, 2CH

Contact

Tablet Oscilloscope Micsig STO1152C, 150MHz, 2CH

Contact

Tablet Oscilloscope Micsig STO1102C, 100MHz, 2CH

Contact