AC power supply Twintex TFC63 Series 500VA-800kVA
AC power supply Twintex TFC63 Series 500VA-800kVA
-
AC Supply Type:
-
AC Power Ouput:
-
AC Voltage Output:
-
AC Current Output:
- Please contact to check stock
- There are currently no promotions for this product
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
- Technical Counseling 100% Free
- Free Shipping For 3.000.000vnd Order
Data is being updated
Description
The TFC63 Series three phase AC power source is high power output three p hase AC power supply, output capacity from 3kVA 6kVA 10kVA 15kVA 20kVA 30kVA to 800kVA. The three phase AC power source features high stability variable voltage output and variable frequency output. Output frequency is variable from 45Hz to 65Hz, or higher frequency at request. The programmable three phase AC power source features fast transient response, response time less than 2mS. The AC power source has over voltage, over current, over temperature and over load protections. The three phase AC power source can be used to simulate grids of different countries, widely used in laboratories, production calibration & test and military applications.
Features
★ Output voltage: phase voltage 0-300V, line voltage 0-520V
★ Output frequency: 50Hz, 60Hz, 47-63Hz, 100Hz, 200Hz, optional 400Hz
★ Phase difference: 120°±2°
★ High accuracy LED display for voltage, current, frequency, active power, power factor
★ Fast transient response, response time no more than 2ms for 100% load and unload
★ Multiple protections: OVP, OCP, OTP and OLP
★ Optional: RS-232/RS-485 interface for PC remote control on output frequency and voltage
★ Optional: DC0-5V analog input for output control
★ Customized specifications and functions acceptable
Specification
Model | Output capacity | Output voltage 1 phase | Output current 1 phase | Weight kg | Dimension WxHxD, mm | |
TFC-6303 | 3KVA | Low 0-150V High 0-300V | Low 0-8.4A High 0-4.2A | 60 | 500x900x680 | |
TFC-6306 | 6KVA | Low 0-150V High 0-300V | Low 0-16.8A High 0-8.4A | 120 | 500x900x680 | |
TFC-6310 | 10KVA | Low 0-150V High 0-300V | Low 0-28A High 0-14A | 150 | 500x900x680 | |
TFC-6315 | 15KVA | Low 0-150V High 0-300V | Low 0-42A High 0-21A | 200 | 500x900x680 | |
TFC-6320 | 20KVA | Low 0-150V High 0-300V | Low 0-58A High 0-29A | 260 | 590x1100x800 | |
TFC-6330 | 30KVA | Low 0-150V High 0-300V | Low 0-84A High 0-42A | 300 | 590x1100x800 | |
TFC-6345 | 45KVA | Low 0-150V High 0-300V | Low 0-126A High 0-63A | 340 | 720x1220x1080 | |
TFC-6360 | 60KV | Low 0-150V High 0-300V | Low 0-168A High 0-84A | 400 | 720x1220x1080 |
Model | 6303 | 6306 | 6310 | 6315 | 6320 | 6330 | 6345 | |||||||
Total output capacity | 3KVA | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA | |||||||
Output capacity/phase | 1KVA | 2KVA | 3.3KVA | 5KVA | 7KVA | 10KVA | 15KVA | |||||||
Circuit mode | IGBT/PWM | |||||||||||||
Input | 3φ4W, 380V±10% 50/60Hz | |||||||||||||
Optional 1φ2W, 220V±10% 50/60Hz | ||||||||||||||
Output | ||||||||||||||
Phase | 3 phase, Phase difference: 120°±2° | |||||||||||||
Low range | Phase voltage 0V-150V, Line voltage 0-260V | |||||||||||||
High range | Phase voltage 0V-300V, Line voltage0-520V | |||||||||||||
Frequency | Adjustable output: 47-63Hz, optional 45-400Hz Fixed output: 50Hz, 60Hz, 100Hz, 200Hz, optional 400Hz | |||||||||||||
Max. current | 0V-150V | 8.4A | 16.8A | 28A | 42A | 58A | 84A | 126A | ||||||
0V-300V | 4.2A | 8.4A | 14A | 21A | 29A | 42A | 63A | |||||||
Frequency accuracy | ≤0.01% | |||||||||||||
Line regulation | ≤1% | |||||||||||||
Load regulation | ≤1% | |||||||||||||
Harmonic distortion | ≤2% (tested with resistive load) | |||||||||||||
Response time | Max. 2ms | |||||||||||||
Efficiency | ≥80% | |||||||||||||
Meter & Resolution | ||||||||||||||
Frequency meter | 4 digits LED, resolution 0.1Hz | |||||||||||||
Voltmeter | 4 digits LED, resolution 0.1V | |||||||||||||
Ammeter | 4 digits LED, resolution 0.1A / 0.01A | |||||||||||||
Power meter | 4 digits LED, resolution 0.01kW/ 0.001kW | |||||||||||||
Preset function | Preset output voltage, output frequency and output voltage floating ratio | |||||||||||||
Hot key function | Hot key for frequency switch, output voltage floating selection | |||||||||||||
Alarm function | Audio and visual alarm started once protection device is activated. Error code will be displayed. | |||||||||||||
Protection | Fuse switch for input and output; Fast-response circuit to detect over voltage, over current, over load, over temperature and short circuit; Output will be shut down in protection mode. | |||||||||||||
Cooling | Forced ventilation | |||||||||||||
Cabinet protection grade | IP2X | |||||||||||||
Operation environment | 0℃-45℃, ≤90% RH(Non-condensing), Altitude: 1500 feet |
Model | 6360 | 63100 | 63150 | 6300 | 63300 | 63400 | 63450 | |||||||
Total output capacity | 60KVA | 100KVA | 150KVA | 200KVA | 300KVA | 400KVA | 450KVA | |||||||
Output capacity/phase | 20KVA | 33KVA | 50KVA | 67KVA | 100KVA | 134KVA | 150KVA | |||||||
Circuit mode | IGBT/PWM | |||||||||||||
Input | 3φ4W, 380V±10% 50/60Hz | |||||||||||||
Output | ||||||||||||||
Phase | 3 phase, Phase difference: 120°±2° | |||||||||||||
Low range | Phase voltage 0V-150V, Line voltage 0-260V | |||||||||||||
High range | Phase voltage 0V-300V, Line voltage0-520V | |||||||||||||
Frequency | 50Hz, 60Hz, 40-70Hz | |||||||||||||
Max. current | 0V-150V | 168A | 276A | 416A | 556A | 834A | 1112A | 1260A | ||||||
0V-300V | 84A | 138A | 208A | 278A | 417A | 556A | 630A | |||||||
Frequency accuracy | ≤0.01% | |||||||||||||
Line regulation | ≤1% | |||||||||||||
Load regulation | ≤1% | |||||||||||||
Harmonic distortion | ≤2% (tested with resistive load) | |||||||||||||
Response time | Max. 2ms | |||||||||||||
Meter & Resolution | ||||||||||||||
Frequency meter | 4 digits LED, resolution 0.1Hz | |||||||||||||
Voltmeter | 4 digits LED, resolution 0.1V | |||||||||||||
Ammeter | 4 digits LED, resolution 0.1A / 0.01A | |||||||||||||
Power meter | 4 digits LED, resolution 0.01kW/ 0.001kW | |||||||||||||
Preset function | Preset output voltage, output frequency and output voltage floating ratio | |||||||||||||
Hot key function | Hot key for frequency switch, output voltage floating selection | |||||||||||||
Alarm function | Audio and visual alarm started once protection device is activated. Error code will be displayed. | |||||||||||||
Protection | Fuse switch for input and output; Fast-response circuit to detect over voltage, over current, over load, over temperature and short circuit; Output will be shut down in protection mode. | |||||||||||||
Cabinet protection grade | IP2X | |||||||||||||
Cooling | Cooling fan | |||||||||||||
Operation environment | 0℃-45℃, ≤90% RH(Non-condensing), Altitude: 1500 feet |