DC Power Supplies Keithley 2231A-30-3 195W 30V, 3A

DC Power Supplies Keithley 2231A-30-3 195W 30V, 3A

SKU:
2231A
Brand:
Warranty:
N/A
Price: Contact
  • Output Channel:
  • Output Current:
  • Output Voltage:
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Description

DC Power Supplies Keithley 2231A-30-3 195W 30V, 3A

Keithley 2231A-30-3 

Features

•  100nA to 6A with high accuracy 

•  Get three isolated, independent, and adjustable outputs in one instrument 

•  Output a total of 195W of power with two 30V@3A outputs and one 5V@3A output 

•  Set voltage outputs with 0.06% basic accuracy and current outputs with 0.2% basic accuracy 

•  Output DC power with less than 5mVp-p noise 

•  Display voltage and current measurements continuously from all three outputs 

•  Double output levels by connecting the two 30V channels in series or parallel 

•  Store frequently used configurations in any of 30 setup memory locations 

•  Turn off any output after a predetermined test time with each channel's output timer 

•  Control the supply from a PC with an optional USB adapter 

Specififcations 

General Specification
 2230-30-1, 2230J-30-12220-30-1, 2230J-30-1
DC Output Rating
Voltage0 to 30 V0 to 30 V0 to 6 V0 to 30 V0 to 30 V
Current0 to 1.5 A0 to 1.5 A0 to 5 A0 to 1.5 A0 to 1.5 A
MAximum Power120 W90 W
Load Regulation
Voltage< 0.01% + 3 mV< 0.01% + 3 mV< 0.01% + 3 mV< 0.01% + 3 mV< 0.01% + 3 mV
Current< 0.01% + 3 mA< 0.01% + 3 mA< 0.01% + 3 mA< 0.01% + 3 mA< 0.01% + 3 mA
Line Regulation
Voltage< 0.01% + 3 mV< 0.01% + 3 mV< 0.01% + 3 mV< 0.01% + 3 mV< 0.01% + 3 mV
Current< 0.01% + 3 mA< 0.01% + 3 mA< 0.01% + 3 mA< 0.01% + 3 mA< 0.01% + 3 mA
Ripple And Noise
Voltage (7MHz)< 1 mV rms < 3 mV p-p< 1 mV rms < 3 mV p-p< 1 mV rms < 3 mV p-p< 1 mV rms < 3 mV p-p< 1 mV rms < 3 mV p-p
Current (20MHz)< 5 mA rms< 5 mA rms< 6 mA rms< 5 mA rms< 5 mA rms
Setting Resolution
Voltage1 mV1 mV1 mV1 mV1 mV
Current1 mA1 mA1 mA1 mA1 mA
Setting Accuracy
Voltage± 0.03% + 10 mV± 0.03% + 10 mV± 0.03% + 10 mV± 0.03% + 10 mV± 0.03% + 10 mV
Current± 0.1% + 5 mA± 0.1% + 5 mA± 0.1% + 5 mA± 0.1% + 5 mA± 0.1% + 5 mA
Meter Resolution
Voltage1 mV1 mV1 mV1 mV1 mV
Current1 mA1 mA1 mA1 mA1 mA
Meter Accuracy
Voltage± 0.03% + 10 mV± 0.03% + 10 mV± 0.03% + 10 mV± 0.03% + 10 mV± 0.03% + 10 mV
Current± 0.1% + 5 mA± 0.1% + 5 mA± 0.1% + 5 mA± 0.1% + 5 mA± 0.1% + 5 mA
Isolation Voltage, Output to ChassisAny output can be floated up to 240V (DC + peak AC with AC limited to a maximum of 3Vpk-pk and a maxi
Isolation Voltage, Output to OutputAny output can be floated up to 240V (DC + peak AC with AC limited to a maximum of 3Vpk-pk and a maximum frequency of 60Hz) relative to any other output terminal.
Voltage transIent response setting time, load CHaNge (typICal)<150ms to within 75mV following a change from 0.1A to 1A
Voltage transIent response settling time, setting change, rIsing (typical)<150ms to within 75mV following a change from 1V to 11V into a 10O resistor (ch. 1,2); from 0.4V to 4V into a 4O resistor (ch. 3.)
Voltage transIent response settling time, setting change, Falling (typical)<150ms to within 75mV following a change from 1V to 11V into a 10O resistor (ch. 1,2); from 0.4V to 4V into a 4O resistor (ch. 3.)
DisplayVacuum fluorescent display
Memory30 setup memories
Tracking and CombInatIon ModesTracking ModeMaintains the ratio on the two 30V output channels that is present when the control is activated
Combination V1+V2 series ModeDeliver up to 60 V when CH1 and CH2 are wired in series. Meter reads back combined voltage
Combination I1+12 parallel ModeDeliver up to 3 A when CH1 and CH2 are wired in parallel. Meter reads back combined current
Rear Panel ConnectionsUSB Device Port, Type B connector, USBTMC compatible
Power Source
110 VAC SettingStandard Versions99 to 121V rms
Japan (J) Versions90 to 110V rms
220 VAC SettingStandard Versions198 to 242V rms
Japan (J) Versions180 to 220V rms
Frequency47Hz to 63Hz
Power ConsumptionStandard Versions450VA
Japan (J) Versions450VA
Physical Characteristics
Protective boots and Handle installedHeight105.3mm (4.15 in.)
Width241.8mm (9.52 in.)
Depth384.0mm (15.12 in.)
Protective boots and Handle RemovedHeight90.7mm (3.57 in.)
Width217.2mm (8.55 in.)
Depth361.6mm (14.24 in.)
Net Weight2220-30-18.2 kg (18 lb.)
2230-30-18.5 kg (19 lb.)
Shipping Weight2220-30-111 kg (24 lb.)
2230-30-111 kg (24 lb.)
Environmental and Safety
TemperatureOperating0° to +40°C
Storage–20° to +70°C
Relative HumidIty (non-condensing):
Operating5% to 95% relative humidity at up to +40°C
Storage5% to 95% relative humidity at up to +40°C. 5% to 60% RH above +40°C up to +70°C, non condensing
AltitudeOperatingUp to 2000m
StorageUp to 4000m
SafetyEuropean UnionComplies with European Union EMC Directive
USANationally recognized testing laboratory listing UL61010-1-2004
CanadaCAN/CSA C22.2 No. 61010-1 2004
ELECTROMAGNETIC COMPATIBIlITY
European UnionComplies with European Union Low Voltage Directive
AustraliaEMC Framework, demonstrated per Emission Standard AS/NZS 2064 (Industrial, Scientific, and Medical Equipment)

Accessories

Regulaterd Powersupply Texio PA36-2B

Contact

Power Supply Chauvinx Arnoux AX0501 (30V-2.5A)

Contact

Power Supply Chauvinx Arnoux AX0502 (30V-2.5A)

Contact

Power Supply Chauvinx Arnoux AX0503 (30V-2.5A)

Contact

Ultra-sensitive Current Sources Keithley 6221 100fA/100mA

Contact

High Power Source Meter Keithley 2657A

Contact

High Power SourceMeter Keithley 2651A

Contact

Source Measure Unit Keithley 2520 700nA/0.33mV

Contact

Source Measure Unit Keithleby 2510

Contact

Source Measure Units Keithley 2510-AT

Contact

Source Meter Unit Keithley 2606B 100fA/100nV

Contact
Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!

Review about this product: