Vector Network Analyzer Siglent SNA5014A 9kHz ~ 8.5GHz
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
- Technical Counseling 100% Free
- Free Shipping For 3.000.000vnd Order
Data is being updated
Description SNA5014A
Low noise floor and a wide dynamic range for accurate measurements System Dynamic range, the difference between the measurement power available at the test port and the noise floor of the receiver is critical parameter of a VNA. The SIGLENT SNA5000A dynamic range is up to 125 dB@10 Hz IFBW, noise floor is down to -125 dBm/Hz, satisfies specific RF test requirements like test passband and out-of-band rejection of filters simultaneously. | |
Abundant measurements and display formats SNA5000A supports scattering-parameter measurement, differential-parameter measurement, receiver measurement, time-domain parameter analysis, limit test, ripple test, enchanced time-domain parameter analysis (TDR). | |
Enhanced Time-Domain Analysis (TDR) The SNA5000A TDR option contains two parts: TDR/TDT(Time Domain Reflection/Transmission) and Eye/Mask. TDR intuitively display impedance discontinuous position and characteristics. It can indicate the impedance of every point along the transmission line, helps to locate fault points. With time domain gating, easily eliminate influences of some kinds of mismatch. It helps to analyze the influences of malfunctions to DUT characteristics. Without the need of an external generator, it can generate eye diagram with internal virtual pattern generator. Eye/Mask is a genuine signal integration analysis tool. Eye function provides high performance waveform simulation ability. Without need to change external connections, it can easily improve signal transmission quality at the transmit end with application of pre-emphasis/de-emphasis technology, while at receive end the equalization technique. Eye function also provides jitter injection function to simulate signals with jitter and to see what effects can it bring to signal transmission. |
Accessories
– USB Cable
– Power cord
– Certificate of calibration
– SNA5000A Quick Start
– Wireless Mouse
– Protective Cover
Please login to write review!