Digital Oscilloscope LeCroy WaveAce 2032 300 MHz, 2 CH
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
- Technical Counseling 100% Free
- Free Shipping For 3.000.000vnd Order
Data is being updated
Máy hiện sóng LeCroy WaveAce 2032 băng thông 300 MHz, 2 kênh, lấy mẫu 1 GSa/s, bộ nhớ 24 kpts, màn hình 7 inch.
- 40 MHz, 60 MHz, 70 MHz, 100 MHz, 200 MHz and 300 MHz bandwidths
- Sample rates up to 2 GS/s
- Long Memory - up to 1 Mpts/Ch (2 Mpts interleaved)
- Advanced Triggering - Edge, Pulse Width, Video, Slope (Rise Time)
- 7" wide screen display
- 32 automatic measurements
- Multi-language user interface and context sensitive help
- Four math functions and FFT
- USB host and device connections for printers, memory sticks and PC remote control
Long memory, high sample rate and easy to use zoom capabilities
Measure with 32 different parameters including advanced timing measurements and a dashboard view
Basic math plus FFT for advanced waveform analysis
Save waveforms, settings and screen captures to a USB device or directly to a PC
Quick mask testing with on screen result counter
Record and playback up to 2,500 waveform captures
Apply digital filters to isolate specific frequencies or eliminate noise
A variety of basic and advanced triggering for capturing a range of different signals
Save up to 20 waveforms and 20 setups to internal memory
Chose from Real Time, Equivalent Time, Peak Detect and Averaging
Vertical System | |
Rise time | 1.2 ns |
Bandwidth | 300 MHz |
Input Channels | 2 |
Bandwidth Limiters | 20 MHz |
Input Impedance | 1 MΩ ± 2% || 18 pF ± 3 pF, 50 Ω ± 2% |
Input Coupling | AC, DC, GND |
Maximum Input Voltage | 1 MΩ: ± 400 Vpk, 50 Ω: 5 VRMS |
Channel-Channel Isolation | ≥ 100:1 at 100 MHz ≥ 50:1 at 150 MHz |
Vertical Resolution | 8 bits |
Sensitivity | 2 mV/div - 5 V/div |
DC Gain Accuracy | ±3%: 5 mV/div - 5 V/div (fixed gain ranges) ±4%: 2mV/div and variable gain ranges |
Offset Range | ±800mV: 2mV/div - 200 mV/div ±40V: 206 mV/div - 5 V/div |
Horizontal System | |
Time/Division Range | 1 ns/div - 50 s/div |
Clock Accuracy | 100 ppm |
Trigger and Interpolator Jitter | .4 ns (pk-pk) |
Acquisition System | |
Single-Shot Sample Rate/Ch | 2 GS/s on 1 Ch 1 GS/s on 2 Ch |
Equivalent Sample Rate | 50 GS/s |
Memory | 24 kpts/Ch on 1 Ch 12 kpts/ch on 2 Ch |
Acquisition Modes | |
Averaging | Selectable Number of Sweeps: 4, 16, 32, 64, 128, 256 |
Peak Detect | 2.5 ns |
Interpolation | Linear, Sin x/x |
Enhanced Resolution | na |
Sequence Mode | na |
Triggering System | |
Modes | Normal, Auto, Single, Stop |
Sources | Ch 1 - Ch 2, EXT, EXT/5, AC Line |
Coupling Mode | AC, DC, LF Rej, HF Rej, |
Pre-trigger Delay | memory/(2 * sample rate) |
Post-trigger Delay | 260 Divisions |
Hold-off by Time or Events | 100 ns - 1.5 s |
Internal Trigger Range | ±6 divisions from center |
Trigger Sensitivity | 1 division: DC - 10 MHz 1.5 divisions: 10 MHz - 300 MHz |
External Trigger Sensitivity | Ext: 200 mVpp from DC to 10 MHz 300 mVpp from 10 MHz to 300 MHz Ext/5: 1Vpp from DC to 10 MHz 1.5 mVpp from 10 MHz to 300 MHz |
External Trigger Input Range | Ext: ±1.2 V, EXT/5: ±6 V |
Display | |
Type | Color 7.0 TFT-LCD |
Resolution | Wide QVGA; 480 x 234 pixels |
Grid Styles | YT (18 horizontal divisions), XY |
Trigger Types | |
Optional Advanced Triggers | na |
Optional Serial Data Triggers | na |
Internal Storage | |
Waveform Storage | 20 waveforms and 2 reference waveforms |
Setup Storage | 20 setups |
Math | |
Number of Math Traces | 1 |
Standard Math Functions | Add, Subtract, Multiply, Divide, FFT |
Optional Math Functions | na |
Measurements | |
Number of Measurements Displayed | 5 |
Measurement Parameters | Amplitude, Average, Base, Burst Width, Cyclical RMS, +Duty Cycle, -Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Preshoot, Rise Time, RMS, Top, +Width, -Width, First Rising-Rising, First Rising-Falling, First Falling-Rising, First Falling-Falling, Last Rising-Rising, Last Rising-Falling, Last Falling-Rising, Last Falling-Falling |
Interface | |
GPIB Port | na |
USB (Device) | 1 |
Ethernet Port | 1 |
USB (Host) | 1 |
Serial Port | na |
Probes | |
Probes | Qty. (2) ÷10/1 Passive Probes |
Scale Factors | Manual: ÷1, ÷10, ÷100, ÷1000 |
Calibration Output | 1 kHz square wave, 3Vp-p (typical), output to probe hook |
Power Requirements | |
Voltage | 100 - 240 VAC, 45 Hz to 440 Hz |
Max. Power Consumption | 50 VA |
Environmental and Safety | |
Temperature (Operating) | 10 °C to 40 °C |
Temperature (Non-Operating) | -20 °C to 60 °C |
Humidity (Operating) | 85% RH, 40 °C |
Humidity (Non-Operating) | 85% RH, 65 °C |
Altitude (Operating) | 3000 m |
Altitude (Non-Operating) | 15,266 m |
Physical Dimensions | |
Dimensions (HWD) | 163 mm x 360 mm x 124.1 mm (6.42 x 14.17 x 4.89) |
Weight | 3.33 kg (7.4 lbs) |
Accessories