Fluke 87V Industrial Multimeter
Hotline: +84 906 988 447
Head Office: Ho Chi Minh City
- Tel: +84 2839 778 269 / 3601 6797
- Email: sales@lidinco.com
- Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam
Office: Bac Ninh City
- Tel: +84 222 730 0180
- Email: bn@lidinco.com
- Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
- Technical Counseling 100% Free
- Free Shipping For 3.000.000vnd Order
Data is being updated
Description
The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment - even in loud, high-energy, and high-altitude locations. The 87V is designed so you can work more efficiently.
Features:
- Identify complex signal problems fast
- Supports accurate measurements on VFDs using a low-pass filter
- Captures intermittents as fast as 250 µS with Peak Capture
Specifications:
Specifications | ||
Voltage DC | Maximum voltage | 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 10 µV | |
Voltage AC | Maximum voltage | 1000 V |
Accuracy | ±(0.7% + 2) True RMS | |
AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
Maximum resolution | 0.1 mV | |
Current DC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.01 µA | |
Current AC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) True RMS | |
Maximum resolution | 0.1 µA | |
Resistance | Maximum resistance | 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Maximum capacitance | 9,999 µF |
accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Maximum frequency | 200 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement | –200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe | |
80 BK temperature probe | –40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater | |
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode | Range | 3 V |
Resolution | 1 mV | |
Accuracy | ±(2% + 1) | |
Duty cycle range | Accuracy | Within ±(0.2% per kHz + 0.1%) |
Environmental Specifications | ||
Operating temperature | –20 °C to + 55 °C | |
Storage temperature | –40 °C to + 60 °C | |
Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) | |
Operating Altitude | 2000 m | |
Safety Specifications | ||
Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV | |
Agency approvals | CE, CSA, RCM | |
Mechanical and General Specifications | ||
Size | 201 x 98 x 52 mm (with holster) | |
Weight | 355 g 624 g – with holster | |
Display | Digital | 6000 counts updates 4/sec. 19,999 counts in high–resolution mode |
Analog | 32 segments, updates 40/sec | |
Frequency | 19,999 counts, updates 3/sec at > 10 Hz | |
Warranty | Lifetime | |
Battery Life | Alkaline | ~400 hours typical, without backlight |
Shock | 1 Meter drop per IEC 61010–1:2001 | |
Vibration | Per MIL–PRF–28800 for a Class 2 instrument |
Accessories
- Fluke TPAK ToolPakTM Magnetic Meter Hanger
- Fluke TL175 TwistGuardTM Test Leads
- Fluke i1010 AC/DC Current Clamp
- Fluke C25 Large Soft Case for DMMs
Please login to write review!