The 6½-digit 2000 Series offers a unique combination of high-precision, cost-effectiveness, and flexibility. Based on the same high-speed, low-noise A/D converter technology found in our 7½- and 8½-digit multimeters, this DMM offers market-leading speed and accuracy. For greater flexibility, a built-in card slot on the rear panel allows an additional multiplexer card for multi-point measurement applications.
Features
- 13 built-in measurement functions
- 2000 readings/second at 4-1/2 digits
- Optional scanner cards for multipoint measurements
- GPIB and RS-232 interfaces
- Fluke 8840/42 command set
General Specification | ||
POWER SUPPLY | 100V / 120V / 220V / 240V | |
LINE FREQUENCY | 50Hz to 60Hz and 400Hz, automatically sensed at power-up | |
POWER CONSUMPTION | 22 VA | |
OPERATING ENVIRONMENT | Specified for 0°C to 50°C. Specified to 80% R.H. at 35°C. Altitude up to 2000 meters. | |
STORAGE ENVIRONMENT | –40°C to 70°C | |
WARRANTY | 1 year | |
EMC | Conforms to European Union EMC Directive | |
SAFETY | Conforms to European Union Low Voltage Directive | |
VIBRATION | MIL-PRF-28800F Class 3 Random | |
WARMUP | 1 hour to rated accuracy | |
DIMENSIONS | Rack Mounting | 89mm high x 213mm wide x 370mm deep (3.5 in. x 8.38 in. x 14.56 in.) |
Bench Configuration (with handle and feet) | 104mm high x 238mm wide x 370mm deep (4.13 in. x 9.38 in. x 14.56 in.) | |
NET WEIGHT | 2.9kg (6.3 lbs) | |
SHIPPING WEIGHT | 5kg (11 lbs) | |
VOLT HERTZ PRODUCT | =8 x 10 7 V·Hz |
DC CHARACTERISTICS | ||||||||
CONDITIONS | MED (1 PLC) 1 or SLOW (10 PLC) or MED (1 PLC) with filter of 10 | |||||||
ACCURACY | ±(ppm of reading + ppm of range) (ppm = parts per million) (e.g., 10ppm = 0.001%) | |||||||
FUNCTION | RANGE | RESOLUTION | TEST CURRENT OR BURDEN VOLTAGE (±5%) | INPUT RESISTANCE | 24 HOUR 23°C ± 1° | 90 DAY 23°C ± 5° | 1 YEAR 23°C ± 5° | TEMPE- RATURE COEFF- ICIENT 0°–18°C & 28°–50°C |
Voltage | 100.0000mV | 0.1 µV | >10GΩ | 30+30 | 40+35 | 50+35 | 2+6 | |
1.000000V | 1.0µV | >10GΩ | 15+6 | 25+7 | 30+7 | 2+1 | ||
10.00000V | 10µV | >10GΩ | 15+4 | 20+5 | 30+5 | 2+1 | ||
100.0000V | 100µV | 10MΩ±1% | 15+6 | 30+6 | 45+6 | 5+1 | ||
1000.000V | 1mV | 10MΩ±1% | 20+6 | 35+6 | 45+6 | 5+1 | ||
Resistance | 100.0000Ω | 100µΩ | 1mA | 30+30 | 80+40 | 100+40 | 8+6 | |
1.000000kΩ | 1mΩ | 1mA | 20+6 | 80+10 | 100+10 | 8+1 | ||
10.00000kΩ | 10mΩ | 100µA | 20+6 | 80+10 | 100+10 | 8+1 | ||
100.0000kΩ | 100mΩ | 10µA | 20+6 | 80+10 | 100+10 | 8+1 | ||
1.000000MΩ | 1Ω | 10µA | 20+6 | 80+10 | 100+10 | 8+1 | ||
10.00000MΩ | 10Ω | 700nA// 10MΩ | 150+6 | 200+10 | 400+10 | 95+1 | ||
100.0000MΩ | 100Ω | 700nA// 10MΩ | 800+30 | 1500+30 | 1500+30 | 900+1 | ||
Current | 10.00000mA | 10nA | <0.15V | 60+30 | 300+80 | 500+80 | 50+5 | |
100.0000mA | 100nA | <0.03V | 100+300 | 300+800 | 500+800 | 50+50 | ||
1.000000A | 1µA | <0.3V | 200+30 | 500+80 | 800+80 | 50+5 | ||
3.00000A | 10µA | <1V | 1000+15 | 1200+40 | 1200+40 | 50+5 | ||
Current | 1 kΩ | 100 mΩ | 1 mA | 40+100 | 100+100 | 120+100 | 8+1 | |
Diode Test | 3.00000V | 10 µV | 1 mA | 20+6 | 30+7 | 40+7 | 8+1 | |
10.00000V | 10 µV | 100µA | 20+6 | 30+7 | 40+7 | 8+1 | ||
10.00000V | 10 µV | 10µA | 20+6 | 30+7 | 40+7 | 8+1 | ||
DC OPERATING CHARACTERISTICS | ||||||||
FUNCTION | DIGITS | READINGS/s | PLCs | |||||
DCV (all ranges), DCI (all ranges), and Ohms (<10M range) | 6.5 | 5 | 10 | |||||
6.5 | 30 | 1 | ||||||
6.5 | 50 | 1 | ||||||
5.5 | 270 | 0.1 | ||||||
5.5 | 500 | 0.1 | ||||||
5.5 | 1000 | 0.04 | ||||||
4.5 | 2000 | 0.01 | ||||||
DC SYSTEM SPEEDS | ||||||||
RANGE CHANGE | 50/s | |||||||
FUNCTION CHANGE | 45/s | |||||||
AUTORANGE TIME | <30 ms | |||||||
ASCII READINGS TO RS-232 (19.2K BAUD) | 55/s | |||||||
MAX. INTERNAL TRIGGER RATE | 2000/s. | |||||||
MAX. EXTERNAL TRIGGER RATE | 500/s | |||||||
DC GENERAL | ||||||||
LINEARITY OF 10VDC RANGE | ±(1ppm of reading + 2ppm of range) | |||||||
DCV, Ω, TEMPERATURE, CONTINUITY, DIODE TEST INPUT PROTECTION | 1000V, all ranges | |||||||
MAXIMUM 4WΩ LEAD RESISTANCE | 10% of range per lead for 100Ω and 1kΩ ranges; 1kΩ per lead for all other ranges | |||||||
DC CURRENT INPUT PROTECTION | 3A, 250V fuse | |||||||
SHUNT RESISTOR | 0.1Ω for 3A, 1A and 100mA ranges. 10Ω for 10mA range | |||||||
CONTINUITY THRESHOLD | Adjustable 1Ω to 1000Ω | |||||||
AUTOZERO OFF ERROR | Add ±(2ppm of range error + 5µV) for <10 minutes and ±1°C change | |||||||
OVERRANGE | 120% of range except on 1000V, 3A and Diode | |||||||
SPEED AND NOISE REJECTION | ||||||||
RATE | READINGS/S | DIGITS | RMS NOISE 10V RANGE | NMRR | CMRR | |||
10 PLC | 5 | 6.5 | < 1.5 µV | 60 dB | 140 dB | |||
1 PLC | 50 | 6.5 | < 4 µV | 60 dB | 140 dB | |||
0.1 PLC | 500 | 5.5 | < 22 µV | 80 dB | ||||
0.01 PLC | 2000 | 4.5 | < 150 µV | 80 dB | ||||
DC Notes | ||||||||
|
TRUE RMS AC VOLTAGE AND CURRENT CHARACTERISTICS | |||||||
ACCURACY | ±(% of reading + % of range), 23°C ±5 °C | ||||||
VOLTAGE RANGE | RESOLUTION | CALIBRATION CYCLE | 3 Hz– 10 Hz | 10 Hz– 20 kHz | 20 kHz– 50 kHz | 50 kHz– 100 kHz | 100 kHz– 300 kHz |
100.0000mV | 0.1 µV | ||||||
1.000000V | 1.0 µV | 90 Days | 0.35+0.03 | 0.05+0.03 | 0.11+0.05 | 0.60+0.08 | 4+0.5 |
10.00000V | 10 µV | ||||||
100.0000V | 100 µV | 1 Year | 0.35+0.03 | 0.06+0.03 | 0.12+0.05 | 0.60+0.08 | 4+0.5 |
750.000V | 1 mV | ||||||
TEMPERATURE COEFFICIENT/°C | 0.035+ 0.003 | 0.005+ 0.003 | 0.006+ 0.005 | 0.01+ 0.006 | 0.03+ 0.01 | ||
CURRENT RANGE | RESOLUTION | CALIBRATION CYCLE | 3 Hz– 10 Hz | 10 Hz– 3 kHz | 3 kHz- 5 kHz | ||
1.000000A | 1 µA | 90 Day/ 1 Year | 0.30+ 0.04 | 0.10+ 0.04 | 0.14+ 0.04 | ||
3.00000A | 10 µA | 90 Day/ 1 Year | 0.35+ 0.06 | 0.15+ 0.06 | 0.18+ 0.06 | ||
TEMPERATURE COEFFICIENT/°C | 0.035+ 0.003 | 0.015+ 0.006 | 0.015+ 0.006 | ||||
HIGH CREST FACTOR ADDITIONAL ERROR ±(% of reading) | |||||||
CREST FACTOR | 1–2 | 2–3 | 3–4 | 4–5 | |||
ADDITIONAL ERROR | 0.05 | 0.15 | 0.30 | 0.40 | |||
AC OPERATING CHARACTERISTICS | |||||||
FUNCTION | DIGITS | READINGS/s | RATE | BANDWIDTH | |||
ACV (all ranges), and ACI (all ranges) | 6.5 | 2s/reading | SLOW | 3 Hz–300 kHz | |||
6.5 | 1.4 | MED | 30 Hz–300 kHz | ||||
6.5 | 4.8 | MED | 30 Hz–300 kHz | ||||
6.5 | 2.2 | FAST | 300 Hz–300 kHz | ||||
6.5 | 35 | FAST | 300 Hz–300 kHz | ||||
ADDITIONAL LOW FREQUENCY ERRORS ±(% of reading) | |||||||
SLOW | MED | FAST | |||||
20Hz – 30Hz | 0 | 0.3 | |||||
30Hz – 50Hz | 0 | 0 | |||||
50Hz – 100Hz | 0 | 0 | 1.0 | ||||
100Hz – 200Hz | 0 | 0 | 0.18 | ||||
200Hz – 300Hz | 0 | 0 | 0.10 | ||||
> 300Hz | 0 | 0 | 0 | ||||
AC SYSTEM SPEEDS | |||||||
FUNCTION/RANGE CHANGE | 4/s | ||||||
AUTORANGE TIME | <3s | ||||||
ASCII READINGS TO RS-232 (19.2k BAUD) | 50/s | ||||||
MAX. INTERNAL TRIGGER RATE | 300/s | ||||||
MAX. EXTERNAL TRIGGER RATE | 300/s | ||||||
AC GENERAL | |||||||
INPUT IMPEDANCE | 1MΩ ±2% paralleled by <100pF | ||||||
ACV INPUT PROTECTION | 1000Vp | ||||||
MAXIMUM DCV | 400V on any ACV range | ||||||
ACI INPUT PROTECTION | 3A, 250V fuse | ||||||
BURDEN VOLTAGE | 1A Range: <0.3V rms. 3A Range: <1V rms | ||||||
SHUNT RESISTOR | 0.1Ω on all ACI ranges | ||||||
AC CMRR | >70dB with 1kΩ in LO lead | ||||||
MAXIMUM CREST FACTOR | 5 at full scale | ||||||
VOLT HERTZ PRODUCT | =8 x 10 7 V·Hz | ||||||
OVERRANGE | 120% of range except on 750V and 3A ranges | ||||||
AC Notes | |||||||
|
Keithley 2000 Product Specifications Summary: (for full specs please see the full specs tab or the data sheet)
Multimeters Template | |
---|---|
Type | Digital |
Style | Bench |
Measures AC V | Yes |
Measures DC V | Yes |
Measures AC A | Yes |
Measures DC A | Yes |
True RMS What's This? | Yes |
Test Equipment General Attributes | |
Power Supply Voltage | 120V 50/60 Hz |
Accessories