  • DC Supply Type:
  • Output Channel:
  • Output Current:
  • Output Voltage:
  • Please contact to check stock
  • There are currently no promotions for this product

Hotline: +84 906 988 447  

Head Office: Ho Chi Minh City

  • Tel: +84 2839 778 269 / 3601 6797
  • Email: sales@lidinco.com
  • Add: 487 Cong Hoa Street, Ward 15, Tan Binh Dist, HCM City, Vietnam

Office: Bac Ninh City

  • Tel: +84 222 730 0180
  • Email: bn@lidinco.com
  • Add: 184 Binh Than Street, Vo Cuong Ward, Bac Ninh City, Vietnam
  • Counseling Technical Counseling 100% Free
  • Shipping Free Shipping For 3.000.000vnd Order
Specification

Data is being updated

Description

DC Power Supplies Keithley 2306

Keithley 2306 

Features

  • Ultrafast response to transient load currents 
  • Choice of single- or dual-channel supplies 
  • Optimized for development and testing of battery-powered devices 
  • Variable output resistance for simulating battery response (U.S. Patent No. 6,204,647) 
  • Pulse peak, average, and baseline current measurements 
  • 100nA DC current sensitivity 
  • Current step measure function 
  • Sink up to 3A 
  • Open sense lead detection 
  • Built-in digital voltmeter 

 Specifications 

GENERAL SPECIFICATIONS
ISOLATION (low–earth)22VDC max
PROGRAMMINGIEEE-488.2 (SCPI)
USER-DEFINABLE POWER-UP STATES8-position quick disconnect terminal block for output (4), sense (2), and DVM (2)
TEMPERATURE COEFFICIENT (outside 23°C ±5°C)Derate accuracy specification by (0.1 × specification)/°C
OPERATING TEMPERATURE0° to 50°C (Derate to 70%). 0° to 35°C (Full power)
STORAGE TEMPERATURE–20° to 70°C.
HUMIDITY<80% @ 35°C non-condensing.
DISPLAY TYPE2-line × 16 character VFD
REMOTE DISPLAY/KEYPAD OPTIONDisables standard front panel
DIMENSIONS89mm high × 213mm wide × 411mm deep (3 1 / 2 in × 8 3 / 8 in × 16 3 / 16 in)
NET WEIGHT3.2kg (7.1 lbs)
SHIPPING WEIGHT5.4kg (12 lbs)
INPUT POWER100–120VAC/220–240VAC, 50 or 60Hz (auto detected at power-up)
POWER CONSUMPTION150VA max
WARRANTYTwo years parts and labor on materials and workmanship
EMCConforms with European Union Directive directive 89/336/EEC, EN 55011, EN 50082-1, EN 61000-3-2 and 61000-3-3, FCC part 15 class B
SAFETYConforms with European Union Directive 73/23/EEC, EN 61010-1
AC LINE LEAKAGE CURRENT450µA @ 110VAC, typ.; 600µA @ 220V, type
RELAY CONTROL PORT4-channel, each capable of 100mA sink, 24V max. Total port sink capacity (all 4 combined) is 250mA max. Accepts DB-9 male plug
ACCESSORIES SUPPLIEDUser and service manual, output connectors mating terminal (part no. CS-846)
ACCESSORIES AVAILABLEModel 2304-DISPRemote LCD Display/Keypad (4.6 in × 2.7 in × 1.5 in). Includes 2.7m (9 ft) cable and rack mount kit

 

DC VOLTAGE OUTPUT (2 YEARS, 23°C ± 5°C)
OUTPUT VOLTAGE0 to +15VDC
OUTPUT ACCURACY±(0.05% + 3mV)
PROGRAMMING RESOLUTION1mV
READBACK ACCURACY±(0.05% + 3mV)
READBACK RESOLUTION1mV
OUTPUT VOLTAGE SETTLING TIME5ms to within stated accuracy
LOAD REGULATION0.01% + 2mV
LINE REGULATION0.5mV
STABILITY0.01% + 0.5mV
MEASUREMENT TIME CHOICES0.01 to 10 PLC 7 , in 0.01PLC steps
AVERAGE READINGS1 to 10
READING TIME31ms, typical
READBACK ACCURACY High BandwidthLow Bandwidth
Transient Recovery Time<40µs or <60µs<80µs or <100µs
Transient Voltage Drop<75mV or <100mV<250mV or <400mV
REMOTE SENSE1V max. drop in each lead. Add 2mV to the voltage load regulation specification for each 1V change in the negative output lead due to load current change. Remote sense required. Integrity of connection continually monitored. If compromised, output will turn off automatically once settable window (±0 to ±8 volts) around normal voltage exceeded.

 

VARIABLE OUTPUT IMPEDANCE
RANGE0 to 1.00? in 0.01? steps. Value can be changed with output on

 

DC CURRENT (2 Years, 23°C ± 5°C)
OUTPUT CURRENT0–4V5A max
>4VI MAX = 60W/(V OUT +6) (not intended to be operated in parallel)
SOURCE COMPLIANCE ACCURACY±(0.16% + 5mA)
PROGRAMMED SOURCE COMPLIANCE RESOLUTION1.25mA
READBACK ACCURACY5A Range±(0.2% + 200µA)
5mA Range±(0.2% + 1µA)
READBACK RESOLUTION5A Range100µA
5mA Range0.1µA
CURRENT SINK CAPACITY0–5V3A max
5V–15VDerate 0.2A per volt above 5V. Compliance setting controls sinking
LOAD REGULATION0.01% + 1mA
LINE REGULATION0.5mA
STABILITY0.01% + 50µA
MEASUREMENT TIME CHOICES0.01 to 10 PLC , in 0.01PLC steps
AVERAGE READINGS1 to 10
READING TIME31ms, typical

 

PULSE CURRENT MEASUREMENT OPERATION
TRIGGER LEVEL5A Range5mA to 5A, in 5mA steps
1A Range1mA to 1A, in 1mA steps
100mA Range0.1mA to 100mA, in 100µA steps
TRIGGER DELAY0 to 100ms, in 10µs steps
INTERNAL TRIGGER DELAY15µs
HIGH/LOW/AVERAGE MODEMeasurement Aperture Settings33.3µs to 833ms, in 33.3µs steps
Average Readings1 to 100
PULSE CURRENT MEASUREMENT ACCURACY 11 (2 Years, 23°C ±5°C)APERTUREACCURACY ±(% reading + offset + rms noise 10 )
<100 µs0.2% + 900 µA + 2 mA
100 µs – 200 µs0.2% + 900 µA + 1.5mA
200 µs – 500 µs0.2% + 900 µA + 1 mA
500 µs – <1 PLC0.2% + 600 µA + 0.8mA
1 PLC0.2% + 400 µA + 0 mA
>1 PLC0.2% + 400 µA + 100 µA

 

PULSE CURRENT MEASUREMENT OPERATION
MEASUREMENT APERTURE33.3µs
CONVERSION RATE3650/second, typical
INTERNAL TRIGGER DELAY15µs
NUMBER OF SAMPLES1 to 5000
TRANSFER SAMPLES ACROSS IEEE BUS IN BINARY MODE4800 bytes/s, typical

 

LONG INTEGRATION MODE CURRENT MEASUREMENT
MEASUREMENT TIME850ms (840ms) to 60 seconds in 1ms steps

 

DIGITAL VOLTMETER INPUT (2 Years, 23°C ± 5°C)
INPUT VOLTAGE RANGE–5 to +30VDC
INPUT IMPEDANCE2M? typical
MAXIMUM VOLTAGE (either input terminal) WITH RESPECT TO OUTPUT LOW–5V, +30V
READING ACCURACY±(0.05% + 3mV)
READING RESOLUTION1mV
CONNECTORHI and LO input pair part of Output #1’s terminal block
MEASUREMENT TIME CHOICES0.01 to 10 PLC 7 , in 0.01PLC steps
AVERAGE READINGS1 to 10

Accessories

  • User and service manual
  • output connectors mating terminal (part no. CS-846)

Regulaterd Powersupply Texio PA36-2B

Contact

Power Supply Chauvinx Arnoux AX0501 (30V-2.5A)

Contact

Power Supply Chauvinx Arnoux AX0502 (30V-2.5A)

Contact

Power Supply Chauvinx Arnoux AX0503 (30V-2.5A)

Contact

Ultra-sensitive Current Sources Keithley 6221 100fA/100mA

Contact

High Power Source Meter Keithley 2657A

Contact

High Power SourceMeter Keithley 2651A

Contact

Source Measure Unit Keithley 2520 700nA/0.33mV

Contact

Source Measure Unit Keithleby 2510

Contact

Source Measure Units Keithley 2510-AT

Contact

Source Meter Unit Keithley 2606B 100fA/100nV

Contact
Reviews & Comments

0.0/5

(0 ratings)
  • 5 0
  • 4 0
  • 3 0
  • 2 0
  • 1 0

Please login to write review!